Skip to main content

ConceptSystem 77

Technical information

Performance

Energy

Thermal insulation - Uf
1.8 W/m²K
Thermal insulation - Uw
1.3 W/m²K
Uw Dependencies
Frame-vent: Ug 1.0W/m²K, warm edge spacer, @1.23x1.48m (102mm sight line), 36mm glass

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class E900 (900Pa)
Wind load resistance
Class C5 (2000Pa)
Acoustics - Rw(C;Ctr)
42(-2; -4) dB
Opening & closing resistance regulation
Class 3

Safety

Burglar resistance
PAS 24,RC2,RC3
Fire resistance
EI₁ 30,EI₂ 30,EI₂ 60,EW 37
Performance and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative for more specific information.

Properties

Sightlines

Min. frame width (inward opening)
51 mm
Min. vent width (inward opening)
33 mm
Min. frame-vent width (inward opening)
89 mm
Min. frame width (outward opening)
17.5 mm
Min. vent width (outward opening)
76 mm
Min. frame-vent width (outward opening)
93.5 mm
Depth frame
68 mm
Depth Vent
77 mm
Depth frame-vent
77 mm

Glazing

Rebate height
25 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - External glazing - Glazing bead
Min. glass thickness - vent
4 mm
Max. glass thickness - vent
63 mm