Product selector

Series

CS 59Pa

Concept System 59 Parallel door
  • Well balanced price-quality-feature mix
  • Minimal build-in depth for insulated system
  • Reduced visible height for doors
Max. height vent3000 mm
Air tightness max. test pressure4 (600 Pa)
Max. width vent1400 mm
Min. Visible width frame-vent: inward opening139 mm
Wind load resistanceC
Energy levelNon Insulated
Series

SlimLine 38

SlimLine 38 aluminium door
  • Well balanced price-quality-feature mix
Max. height vent2500 mm
Air tightness max. test pressure3 (600 Pa)
Acoustic performanceRw(C;Ctr) = 38 (-1; -4) dB / 45 (-1; -5) dB
Max. width vent1250 mm
Water tightness4A (150 Pa)
Thermal insulation (Uf)1,9 W/m²K
Min. Visible width frame-vent: inward opening101.5 mm
Wind load resistanceC3 (1200 Pa)
Burglar resistanceRC2/WK2
Energy levelSuper High
Series

ES 45Pa

ES 45Pa door
Max. height vent2400 mm
Air tightness max. test pressure4 (600 Pa)
Max. width vent1400 mm
Water tightness7A (300 Pa)
Min. Visible width frame-vent: inward opening115 mm
Wind load resistanceC2 (800 Pa)
Energy levelNon Insulated
Series

Vision 50

Commercial aluminium door for high traffic applications
Series

MasterLine 8

MasterLine 8 'door'
  • High air, wind & water tightness performances
  • Well balanced price-quality-feature mix
  • Wide field of applicability
Max. height vent3000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw (C; Ctr) = 43 (-1; -4) dB
Max. Glass thickness vent58 mm
Max. width vent1400 mm
Water tightness7A (300 Pa)
Thermal insulation (Uf)153mm HI: 2,2; HI+: 1,4 W/m²K
Min. Visible width frame-vent: inward opening153 mm
Wind load resistanceC3 (1200 Pa)
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelPassive
Series

CS 77

Concept System 77 aluminium door
Max. height vent3000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw (C; Ctr) = 42 (-1; -4) dB
Max. Glass thickness vent52 mm
Max. width vent1400 mm
Water tightness7A (300 Pa)
Thermal insulation (Uf)150mm: 2,1 W/m²K
Min. Visible width frame-vent: inward opening150 mm
Wind load resistanceC2 (800 Pa)
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelHigh
Series

CS 68

Concept System 68 aluminium door
  • Well balanced price-quality-feature mix
  • Minimal build-in depth for doors
  • Reduced visible height for fixed windows and opening windows
Max. height vent3000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw (C; Ctr) = 37 (-1; -4) / 44 (-2; -5) dB
Max. width vent1400 mm
Water tightness4A (150 Pa)
Min. Visible width frame-vent: inward opening150 mm
Wind load resistanceC4 (1600 Pa)
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelHigh
Series

ES 50

Eco System aluminium door
  • Well balanced price-quality-feature mix
  • Minimal build-in depth for insulated system
  • Reduced visible height for doors
Max. height vent3000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw (C; Ctr) = 40 (-2; -4) dB
Max. width vent1400 mm
Water tightness4A (150 Pa)
Thermal insulation (Uf)3,2 W/m²K
Min. Visible width frame-vent: inward opening146 mm
Wind load resistanceC2 (800 Pa)
Energy levelHigh
Series

CS 59

Concept System 59 door
  • Well balanced price-quality-feature mix
  • Minimal build-in depth for insulated system
  • Reduced visible height for doors
Max. height vent3000 mm
Air tightness max. test pressure2 (300 Pa)
Acoustic performanceRw (C; Ctr) = 40 (-2; -4) dB
Max. width vent1400 mm
Water tightness4A (150 Pa)
Min. Visible width frame-vent: inward opening149 mm
Wind load resistanceC
Energy levelMedium
Series

MasterLine 8

MasterLine 8 window
  • High air, wind & water tightness performances
  • Excellent thermal values
  • Increased productivity
Max. height vent2800 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performance45 (-1;-4) dB
Max. Glass thickness vent68 mm
Max. width vent1200 mm
Water tightnessE900 (900 Pa)
Thermal insulation (Uf)119mm: St. 1,9 / HI 1,6 / HI+1,2 W/m²K
Min. Visible width frame-vent: inward opening97 mm
Wind load resistanceC5 (2000 Pa)
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelPassive
Series

SlimLine 38

SlimLine 38 aluminium window
  • 40mm Thermal break on frame 32mm thermal break on vent
  • 10mm Frame-vent rebate
  • 13.5mm glass rebate
Max. height vent2800 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performance45 dB
Max. Glass thickness vent55 mm
Max. width vent1200 mm
Water tightness9A (600 Pa)
Thermal insulation (Uf)1,9 W/m²K
Min. Visible width frame-vent: inward opening67 mm
Wind load resistanceC4 (1600 Pa)
Burglar resistanceRC2/WK2
Energy levelSuper High
Series

SlimLine 68

SlimLine 68 window
  • Ultra slim sightlines
  • Optimal daylight access
Max. height vent1500 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performance47(-2;-7) dB
Max. Glass thickness vent43 mm
Max. width vent1200 mm
Water tightnessE1200 (1200 Pa)
Thermal insulation (Uf)1,4 W/m²K
Wind load resistanceExxx (>2000 Pa)
Burglar resistancePAS 24
Energy levelHigh
Series

CS 77

Concept System 77 aluminium window
  • Well balanced price-quality-feature mix
  • Minimal build-in depth for insulated system
  • Reduced visible height for fixed windows and opening windows
Max. height vent2800 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performance42 (-2; -4) dB
Max. Glass thickness vent63 mm
Max. width vent1200 mm
Water tightness9A (600 Pa)
Thermal insulation (Uf)1.8 W/m²K
Min. Visible width frame-vent: inward opening89 mm
Wind load resistanceC3 (1200 Pa)
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelHigh
Series

CS 68

Concept System 68 aluminium window
  • Well balanced price-quality-feature mix
  • Minimal build-in depth for insulated system
  • Compatible with the Ventalis ventilation unit
Max. height vent2800 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performance46(-2;-8) dB
Max. Glass thickness vent54 mm
Max. width vent1200 mm
Water tightness9A (600 Pa)
Thermal insulation (Uf)1,8 W/m²K
Min. Visible width frame-vent: inward opening89 mm
Wind load resistanceC4 (1600 Pa)
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelHigh
Series

ES 50

Eco System 50 aluminium window
  • Well balanced price-quality-feature mix
  • Minimal build-in depth for insulated system
  • Reduced visible height for fixed windows and opening windows
Max. height vent2200 mm
Air tightness max. test pressure4 (600 Pa)
Max. Glass thickness vent32 mm
Max. width vent800 mm
Water tightness9A (600 Pa)
Thermal insulation (Uf)2,2 W/m²K
Min. Visible width frame-vent: inward opening86 mm
Wind load resistanceC4 (1600 Pa)
Burglar resistanceWK2
Energy levelHigh
Series

Hi-Finity

Hi-Finity aluminium sliding door
  • Ultimate design freedom, matching each project requirement
  • Floor-to-ceiling and wall-to-wall fully concealed profiles
  • Elegant lines and an unobstructed view
Max. height vent4000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 43 (-1;-3) dB
Max. width vent3500 mm
Water tightnessE750 (750 Pa)
Thermal insulation (Uf)1.4 W/m²K
Wind load resistanceC5 (2000 Pa)
Burglar resistanceRC2/WK2
Energy levelPassive
Series

MasterPatio

  • Standard high-insulating system with high-rise ready performances.
  • Sustainable through recycled materials and reduced waste during production.
  • Compatible with our MasterLine 8 system, converting it into an easy to produce floor-to-ceiling facade.
Max. height vent3600 mm
Air tightness max. test pressure4 (600 Pa)
Max. width vent3000 mm
Water tightnessE1200 (1200 Pa)
Wind load resistanceC5 (2000 Pa)
Energy levelPassive
Series

CP 155 (-LS)

Concept Patio 155 aluminium sliding door
  • A high end complete sliding door solution which makes the combination of high insulation and large dimensions possible
  • Based on the exquisite know how of Reynaers regarding sliding doors
  • Fabrication and logistical ease; minimal number of profiles, compatible with CS 77
Max. height vent3500 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw (C; Ctr) = 35 (-2;-5) / 42 (-1;-3) dB
Max. width vent2700 mm
Water tightnessE900 (900 Pa)
Thermal insulation (Uf)1,07 W/m²K
Wind load resistanceC4 (1600 Pa)
Burglar resistanceRC2/WK2
Energy levelSuper High
Series

CP 130 (-LS)

Concept Patio 130 aluminium sliding door
  • The complete sliding door solution hich offers a large choice in designs and functionalities
  • Based on the exquisite know how of Reynaers regarding sliding doors
  • Fabrication and logistical ease; minimal number of profiles, compatibel with CS 68
Max. height vent2700 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw (C; Ctr) = 35 (-2;-6) / 39 (-1;-3) dB
Max. width vent2700 mm
Water tightnessE750 (750 Pa)
Thermal insulation (Uf)2,35 W/m²K
Wind load resistanceB5 (2000 Pa)
Burglar resistanceRC2/WK2
Energy levelHigh
Series

CP 68

Concept Patio 68
Max. height vent2500 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw (C; Ctr) = 31 (-1;-5) / 38 (-2;-5) dB
Max. width vent1500 mm
Water tightness7B (300 Pa)
Thermal insulation (Uf)2.51 W/m²K
Wind load resistanceC4 (1600 Pa)
Burglar resistanceRC2/WK2
Energy levelSuper High
Series

CF 77

Concept Folding 77 aluminium sliding folding door
  • Standalone folding system
  • Large variety of configurations (from 2 to 8 vents)
  • Symmetrical design: In- and outward opening with same profiles & accessories
Max. height vent3000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw (C; Ctr) = 34 (-2;-5) / 45 (-1;-5) dB
Max. width vent1200 mm
Water tightness9A (600 Pa)
Thermal insulation (Uf)2,25 W/m²K
Wind load resistanceC3 (1200 Pa)
Burglar resistanceRC2/WK2
Energy levelSuper High
Series

CF 68

Concept Folding 68 aluminium sliding folding door
  • wide range of configurations up to 8 vents
  • High AWW performance and burglar resistance class RC2 with 2 point locking gear to provide maximum comfort and security
  • Compatible with other Reynaers systems
Max. height vent2500 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw (C; Ctr) = 35 (-1;-4) / 40 (-2;-4) dB
Max. width vent1200 mm
Water tightness9A (600 Pa)
Thermal insulation (Uf)1,8 W/m²K
Wind load resistanceB3 (1200 Pa)
Burglar resistanceRC2/WK2
Energy levelSuper High
Series

CW 50

Concept Wall 50 aluminium curtain walling
  • High performance towards Air, wind and water testing
  • High insulative compared with comparable sections
  • High maximal dimensions, possible to build large elements.
Air tightness max. test pressure1200
Acoustic performance60 (-2;-6) dB
Water tightness1200 Pa
Thermal insulation (Uf)0,8 W/m²K
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelHigh
Series

CW 60

Concept Wall 60 aluminium curtain wall
  • High performance towards air, wind and water testing
  • High insulative compared with comparable sections
  • High maximal dimensions, possible to build large elements
Max. height vent2000 mm
Air tightness max. test pressure4 (600 Pa)
Max. width vent2500 mm
Water tightness1200
Wind load resistanceExxx (>2000 Pa)
Energy levelHigh
Series

CW 65-EF

Concept Wall 65 'Element Façade' aluminium curtain wall
  • Slim line design with a minimal joint between the glazing beads or glass panes
  • High performance towards air, wind and water testing
  • High insulative compared with comparable sections
Max. height vent3700 mm
Air tightness max. test pressureAE 700 (700 Pa)
Max. width vent1600 mm
Water tightness1200
Thermal insulation (Uf)2,54 W/m²K
Energy levelHigh
Series

CW 86

Concept Wall 86 aluminium curtain wall
  • Slim line design with a minimal joint between the glazing beads or glass panes
  • High performance towards air, wind and water testing
  • High insulative compared with comparable sections
Water tightnessRE1050 (1050 Pa)
Thermal insulation (Uf)3,9 W/m²K
Wind load resistanceB5 (2000 Pa)
Energy levelHigh
Series

BS 100

Brise Soleil 100
  • Watertight connection guiding the cables to the inside of the CW 60 system
  • Connection to CW 50
Series

BS 40

Brise Soleil 40
Series

BS 30

Brise Soleil 30
Series

Reynascreen

Reynascreen
Series

CR 120

CR 120 Conservatories
Air tightness max. test pressure1 (150 Pa)
Series

TR 200

Thermo Roof 200 Conservatories
Air tightness max. test pressure3 (600 Pa)
Water tightness9A (600 Pa)
Thermal insulation (Uf)1,8 W/m²K
Wind load resistanceC2 (800 Pa)
Series

PR 100

PR 100 Conservatories
Series

Cintro

Cintro Canopy System
  • The system is extremely suitable for aluminium arched spans
  • The minimum radius is 400mm
  • The flat shells give the roof a streamlined finish
Series

RB 10

Ensured safety
Series

Mosquito

Keep out insects
Series

Ventalis

Ventilation System
  • Fully integrated solution
  • Anchoring on top of the elements with Ventalis is identical as anchoring without Ventalis to guarantee severe building connection
  • Large choice of applications, configuration and design modularity without limitation towards the needed airflow
Series

Shield

Reliability
Series

Horizon

Sleek & Modern design.
Burglar resistanceRC2/WK2 - SKG 2
Series

Contour

Modern safety
  • Robust Stainless Steel
  • Hygienic, durable material
  • Safety variants with slim long faceplate
Burglar resistanceRC2/WK2 - SKG 3
Series

Orchid

Elegance
Series

Reynaseal Duo

Reynaseal Duo Glue
Series

Reynafinish 60

Reynafinish 60 Cleaner
Series

Reynaprotector

Reynaprotector
Series

Manual Gun

Manual & Pneumatic Gune
Series

Mixing Tubes

Mixing Tubes
Series

Handle for Foam Rollers

Handle for Foam Rollers
Series

Reynawash Color

Reynawash Color
Series

Reynawash Ano

Reynawash Ano
Series

Reynovator 718

- All-in-one total renovation oil- Used for restoration, conservation and maintenance of already installed aluminium systems (powder coated and anodized)- Protection against oxidation- Adds gloss- Restores protective coating
Series

Pneumatic Gun